WinSyslog Event ID 11019: Syslog Queue action has no queue name#

Answer#

The product cannot initialize the Syslog Queue action because its required queue name is empty.

Event details#

  • Event ID: 11019

  • Severity: Error

  • Component: Syslog Queue action

  • Windows Event Log source: AdisconWinSyslog

  • Available since: 26.07

  • Message pattern: Failed to initialize Syslog Queue action: the configured queue name is empty.

Possible causes#

  • The queue name was never configured.

  • A configuration import or manual file edit removed the queue name.

  • The action configuration is incomplete.

Immediate checks#

  1. Open the affected Syslog Queue action.

  2. Configure a non-empty queue name that matches the intended queue consumer.

  3. Validate and reload the configuration.

Detailed procedures#

Verify the result#

Send a controlled event through the action and confirm that it enters the named queue without another Event ID 11019.

Evidence to collect#

  • The complete Windows Application Event Log entry and neighboring product events from the same time window.

  • The exact product version, affected service or action name, and event timestamp with time zone.

  • The affected configuration object and a bounded debug log covering one controlled reproduction.

  • Remove passwords, tokens, license data, private keys, message payloads, personal data, and customer-identifying names, addresses, hostnames, domains, and network addresses before sharing evidence.

Escalation#

If the event continues after the detailed procedures, collect the listed evidence and contact Adiscon Support.