WinSyslog Event ID 11019: Syslog Queue action has no queue name#
Answer#
The product cannot initialize the Syslog Queue action because its required queue name is empty.
Event details#
Event ID:
11019Severity: Error
Component: Syslog Queue action
Windows Event Log source:
AdisconWinSyslogAvailable since: 26.07
Message pattern: Failed to initialize Syslog Queue action: the configured queue name is empty.
Possible causes#
The queue name was never configured.
A configuration import or manual file edit removed the queue name.
The action configuration is incomplete.
Immediate checks#
Open the affected Syslog Queue action.
Configure a non-empty queue name that matches the intended queue consumer.
Validate and reload the configuration.
Detailed procedures#
Diagnose an action backlog or disk queue — Identify why queued work is not draining while preserving data.
Validate configuration and reload it safely — Back up, inspect, correct, and test the exact invalid configuration object.
Collect an Event ID and neighboring product events — Preserve the complete event and the product events immediately before and after it.
Export configuration and collect a bounded debug log — Create a text configuration export and time-bounded debug capture, then disable debugging.
Verify the result#
Send a controlled event through the action and confirm that it enters the named queue without another Event ID 11019.
Evidence to collect#
The complete Windows Application Event Log entry and neighboring product events from the same time window.
The exact product version, affected service or action name, and event timestamp with time zone.
The affected configuration object and a bounded debug log covering one controlled reproduction.
Remove passwords, tokens, license data, private keys, message payloads, personal data, and customer-identifying names, addresses, hostnames, domains, and network addresses before sharing evidence.
Escalation#
If the event continues after the detailed procedures, collect the listed evidence and contact Adiscon Support.