WinSyslog Event ID 11072: DTLS listener: listener could not bind to its configured address#

Answer#

DTLS listener: listener could not bind to its configured address. The product recorded this while processing dtls listener; the appended event detail identifies the affected object, operation, or provider error.

Event details#

  • Event ID: 11072

  • Severity: Error

  • Component: DTLS listener

  • Windows Event Log source: AdisconWinSyslog

  • Available since: 26.07

  • Message pattern: DTLS listener: listener could not bind to its configured address. Additional detail: {event_detail}

Possible causes#

  • The destination or listener is unavailable, blocked, bound to another address or port, or configured for a different transport.

  • TLS certificates, peer authorization, protocol settings, or sender and receiver configuration do not match.

Immediate checks#

  1. Record the endpoint, address family, port, transport, TLS mode, and complete runtime detail.

  2. Verify DNS, route, listener ownership, firewall policy, and TCP or UDP reachability as applicable.

  3. Send one unique test message and verify positive receipt and queue recovery.

Detailed procedures#

Verify the result#

Repeat or monitor the affected operation and confirm that Event ID 11072 does not recur and that dtls listener processing continues.

Evidence to collect#

  • The complete Windows Application Event Log entry, including all event detail.

  • The product name, exact version, service account, and event timestamp with time zone.

  • A configuration export and debug log covering the same time window, with secrets removed.

Escalation#

If the event continues after the detailed procedures, collect the listed evidence and contact Adiscon Support.