WinSyslog Event ID 11113: Syslog listener: service component initialization failed#

Answer#

Syslog listener: service component initialization failed. The product recorded this while processing syslog listener; the appended event detail identifies the affected object, operation, or provider error.

Event details#

  • Event ID: 11113

  • Severity: Error

  • Component: Syslog listener

  • Windows Event Log source: AdisconWinSyslog

  • Available since: 26.07

  • Message pattern: Syslog listener: service component initialization failed. Additional detail: {event_detail}

Possible causes#

  • The destination or listener is unavailable, blocked, bound to another address or port, or configured for a different transport.

  • TLS certificates, peer authorization, protocol settings, or sender and receiver configuration do not match.

Immediate checks#

  1. Record the endpoint, address family, port, transport, TLS mode, and complete runtime detail.

  2. Verify DNS, route, listener ownership, firewall policy, and TCP or UDP reachability as applicable.

  3. Send one unique test message and verify positive receipt and queue recovery.

Detailed procedures#

Verify the result#

Repeat or monitor the affected operation and confirm that Event ID 11113 does not recur and that syslog listener processing continues.

Evidence to collect#

  • The complete Windows Application Event Log entry, including all event detail.

  • The product name, exact version, service account, and event timestamp with time zone.

  • A configuration export and debug log covering the same time window, with secrets removed.

Escalation#

If the event continues after the detailed procedures, collect the listed evidence and contact Adiscon Support.